Contact us
+34 93 219 43 50 | This email address is being protected from spambots. You need JavaScript enabled to view it.

ACS CP QUESTIONNAIRE

Questionnaire for cathodic protection installation in large and existing ACS storage tanks

version 08/01.13

* Mandatory information.
...........................................................................................................

1. Scope

The aim of this document is to obtain all the significant data who allow us to analyze if is feasible to install a cathodic protection system in large ACS storage tanks and also to prepare a pre-design and commercial proposal.
The technical paper HT-40 “Recuperación de grandes acumuladores de agua caliente sanitaria corroídos”is a complementary document which is intended to clarify some details.
Once the GULDAGER cathodic protection system is installed the storage tanks is able to fulfil the requirements of the Spanish royal law 865/2003 regarding legionella prevention by the internal clean-up and disinfection.
Chapter 6.4.4.3.5 of Standard UNE 112076 “Corrosion prevention in hot water systems” addresses the rehabilitation of existing storage tanks by cathodic protection.
The cathodic protection system installed by GULDAGER complies with UNE-EN-12499 standard “Internal cathodic protection of steel structures”.

...........................................................................................................

2. Client Data
...........................................................................................................
3. ACS storage tank features
3.8. Heating system:
It´s necessary to know if the manhole available diameter is 400mm as minimum to be able to access to the tank interior. Before completing the questionnaire this diameter shall be measured and confirmed.
3.12. Storage tanks status:
...........................................................................................................
4. ACS piping
...........................................................................................................
...........................................................................................................
...........................................................................................................
7. LOPD+LSSI Clause (*)
...........................................................................................................
Size limit for each file is 20 MB

...........................................................................................................

(*) LOPD+LSSI CLAUSE
In conformity with Organic Law 15/1999 we inform you that all your data will be included in a master data archive under WWI GULDAGER ELECTROLISIS, S.A. responsibility in order to attend all involved requirements requested by you.
You may exercise your rights for access, cancelation, revision and opposition by a written letter to our address C/ TORRENT DE L'ESTADELLA, 41, Nave 08030 BARCELONA.
Until you tell us otherwise, we understand that your data has not been modified, you agree to notify any change and request consent to process your data in accordance with the purpose mentioned.
According to Law 34/2002 of Services of the Information Society and Electronic Commerce in article 21 we request your consent to make commercial offers, marketing and advertising of our products and services by email or any other means of electronic communication.

Prev Next

Protección Catódica Guldager en Twentytú…

This page has not been translated yet. Sorry for the inconvenience. Durante el próximo mes de Julio se cumplirán 5 años...

Read more

25 Años de protección catódica Guldager …

This page has not been translated yet. Sorry for the inconvenience. El próximo mes de Junio se cumplirán 25 años desde...

Read more

Metropolitan confía en Guldager

This page has not been translated yet. Sorry for the inconvenience. Metropolitan es la mayor cadena española de centros de Deporte,...

Read more

Guldager ha participado en Climatización…

This page has not been translated yet. Sorry for the inconvenience. El pasado 1 de Marzo, Adrià Gomila, presidente de Guldager...

Read more

Prevención del desarrollo de la legionel…

Prevención del desarrollo de la legionella evitando el óxido en los grandes acumuladores de ACS

This page has not been translated yet. Sorry for the inconvenience. El próximo 16 de febrero, en el marco del VII...

Read more

Mantenimiento del sistema de protección …

This page has not been translated yet. Sorry for the inconvenience. Aernnova, empresa líder en el diseño y fabricación de estructuras...

Read more

Guldager protege los nuevos acumuladores…

This page has not been translated yet. Sorry for the inconvenience. El Hotel H10 Playa Meloneras Palace es un Resort de...

Read more

Protección catódica Guldager y garantía …

This page has not been translated yet. Sorry for the inconvenience. Poco antes de finalizar la reforma del Hospital FREMAP Barcelona,...

Read more

Garantía contra la corrosión interior de…

This page has not been translated yet. Sorry for the inconvenience. Guldager tiene el placer de presentarles un artículo sobre la Garantía...

Read more

Jornadas Técnicas 2016

This page has not been translated yet. Sorry for the inconvenience. 18 Mayo 2016 Jornada Técnica Edificios. Organizado por AEM y...

Read more